Product data sheet:
Ionizing Air Knife Series RA ION 575 - L 645 mm
| Range | Blowing |
|---|---|
| Category | Air curtains |
| Kind | Ionizing |
| Matter | Aluminum |
| Length | 645 mm |
| Consumption | 1965 Nl/min at 5 |
RA ION series ionizing air curtains neutralize electrostatic charges and remove unwanted particles. Combining an antistatic bar with an air curtain, these ionizing air curtains can effectively remove dust and provide optimal static dust removal.
RA ION 575 specifications
• Supplied with 3 metres of cable
• Optional generator
TECHNICAL INFORMATION
| BENEFITS OF USING THE AIR CURTAIN* (compared with an open pipe) |
Reduction in air consumption (%) |
Noise reduction (%) | ||||||
|---|---|---|---|---|---|---|---|---|
| up to -93% |
up to -29% |
|||||||
| PERFORMANCE OF THE AIR CURTAIN* |
Pressure (bar) | Air consumption (l/min) | Thrust force (N) | Noise level (dB) | Blowing flow (l/min) | |||
| at 150mm | at 450mm | |||||||
| 2 | 1100 | 5.9 | 5.3 | 85 | 27500 | |||
| 6 | 2900 | 15.1 | 15 | 95 | 72500 | |||
| VS | ||||||||
| OPEN PIPE Ø8 INTERNAL* (cut to 600 mm) |
Pressure (bar) | Air consumption (l/min) | Noise level (dB) | Blowing flow (l/min) | ||||
| 6 | 22350 | 130 | 22350 | |||||
Note: The distances indicated below apply to the ionizing bar alone. The range of the antistatic treatment is increased by the airflow generated by the air curtain, improving treatment efficiency and extending the working distance. Please refer to the technical data sheet for the maximum distances.
Ionizing bar technical data |
|||
|---|---|---|---|
| Operating voltage | MAX 7kV AC | Distance between discharge electrodes | 25 mm |
| Operating current | MAX 5 mA | Discharge electrode material | stainless steel / tungsten |
| Operating frequency | 50/60 Hz | Length | 80~4000 mm |
| Operating mode | Industrial-frequency AC | Operating temperature | 0~50°C |
| Operating distance | 30~150 mm | Operating humidity | 0~70% RH (no condensation or frost) |
| Recommended installation distance | 30~50 mm | Test conditions | Temperature (23±3) °C; Humidity (50±5) %; Test voltage ±1 kV~±100 V |
Static elimination speed ≤ 0.1 second
The discharge electrode is insulated using a special process to eliminate static electricity quickly, safely and efficiently.