NOVACOM, the widest range of vacuum components in Europe.

Blowing / Air curtains / Ionising air curtains / Ionizing Air Knives Series RA ION 125 - L 195MM

Product data sheet:

Product reference: RA ION 125
Catalogue price: On quotation

Ionizing Air Knives Series RA ION 125 - L 195MM

Characteristics:
Range Blowing
Category Air curtains
Kind Ionizing
Matter Aluminum
Length 195 mm
Consumption 645 Nl/min at 5
File to download:
File STEP
Ionizing Air Knives Series RA ION 125 - L 195MM

RA ION series ionizing air curtains neutralize electrostatic charges and remove unwanted particles. Combining an antistatic bar with an air curtain, these ionizing air curtains can effectively remove dust and provide optimal static dust removal.

RA ION 125 specifications

• Supplied with 3 metres of cable
• Optional generator

TECHNICAL INFORMATION

BENEFITS OF USING
THE AIR CURTAIN
(compared with an open pipe)
Reduction in
air consumption (%)
Noise reduction (%)
up to

-92%
up to

-39%
PERFORMANCE
OF THE AIR CURTAIN*
Pressure (bar) Air consumption (l/min) Thrust force (N) Noise level (dB) Blowing flow (l/min)
at 150mm at 450mm
2 450 2 2 79 6000
6 1150 8 7.3 90 23000
VS    
OPEN PIPE
Ø8 INTERNAL*
(cut to 150 mm)
Pressure (bar) Air consumption (l/min) Noise level (dB) Blowing flow (l/min)  
6 5700 130 5700  
   

 


 

Note: The distances indicated below apply to the ionizing bar alone. The range of the antistatic treatment is increased by the airflow generated by the air curtain, improving treatment efficiency and extending the working distance. Please refer to the technical data sheet for the maximum distances.

Ionizing bar technical data

Operating voltage MAX 7kV AC Distance between discharge electrodes 25 mm
Operating current MAX 5 mA Discharge electrode material stainless steel / tungsten
Operating frequency 50/60 Hz Length 80~4000 mm
Operating mode Industrial-frequency AC Operating temperature 0~50°C
Operating distance 30~150 mm Operating humidity 0~70% RH (no condensation or frost)
Recommended installation distance 30~50 mm Test conditions Temperature (23±3) °C; Humidity (50±5) %; Test voltage ±1 kV~±100 V



Static elimination speed ≤ 0.1 second

The discharge electrode is insulated using a special process to eliminate static electricity quickly, safely and efficiently.
datas_ion.png

Quote Request

Total items: 0

Your cart is empty.

Your company details