Type | Multi Stage |
---|---|
Series | VME-2 |
Vacuum | 82% |
Suction capacity | 400 l/min at 6 bar |
Principle The multi-stage VME ejectors suck a large volume of air at start-up. They operate on the principle of the series mounted ejector. The ratio between the sucked air flow and the used air flow is excellent. For visual verification of the partial vacuum, a vacuum gauge is installed on the ejector. Specifications of the VME-2 25 - Air sucked at 4 bar: 320 Nl/min i.e. 5.33 l/sec or 19.20 m3/h - Vacuum at 4 bar (%): 70 - Air usage at 4 bar (Nl/min): 126 - Air sucked at 6 bar: 400 Nl/min i.e. 6.67 l/sec or 24.00 m3/h - Vacuum at 6 bar (%): 82 - Air usage at 6 bar (Nl/min): 180 - Weight (g): 654 - Silencer model: SIL 12